Abstract
Objective
The initiation of extracorporeal membrane oxygenation (ECMO) triggers complex coagulation processes necessitating systemic anticoagulation. Therefore, anticoagulation monitoring is crucial to avoid adverse events such as thrombosis and hemorrhage. The main aim of this work was to analyze the association between anti-Xa levels and thrombosis occurrence during ECMO support.
Design
Systematic literature review and meta-analysis (Scopus and PubMed, up to July 29, 2023).
Setting
All retrospective and prospective studies.
Participants
Patients receiving ECMO support.
Intervention
Anticoagulation monitoring during ECMO support.
Measurements and Main Results
A total of 16 articles with 1,968 patients were included in the review and 7 studies in the meta-analysis (n = 374). Patients with thrombosis had significantly lower mean anti-Xa values (standardized mean difference -0.36, 95% confidence interval [CI] -0.62 to -0.11, p < 0.01). Furthermore, a positive correlation was observed between unfractionated heparin infusion and anti-Xa levels (pooled estimate of correlation coefficients 0.31, 95% CI 0.19 to 0.43, p < 0.001). The most common adverse events were major bleeding (42%) and any kind of hemorrhage (36%), followed by thromboembolic events (30%) and circuit or oxygenator membrane thrombosis (19%). More than half of the patients did not survive to discharge (52%).
Conclusions
This work revealed significantly lower levels of anti-Xa in patients experiencing thromboembolic events and a positive correlation between anti-Xa and unfractionated heparin infusion. Considering the contemplative limitations of conventional monitoring tools, further research on the role of anti-Xa is warranted. New trials should be encouraged to confirm these findings and determine the most suitable monitoring strategy for patients receiving ECMO support.