Tags Archives: IABP

thumbnail
0 comment

Left Ventricular Unloading With Impella Versus IABP in Patients With VA-ECMO: A Systematic Review and Meta-Analysis

Abstract Venoarterial extracorporeal membrane oxygenation (VA-ECMO) use for circulatory support in cardiogenic shock results in increased left ventricular (LV) afterload. The use of concomitant Impella or intra-aortic balloon pump (IABP)..

Read More
thumbnail
0 comment

Perspectives and Considerations of IABP in the Era of ECMO for Cardiogenic Shock

Abstract The development of mechanical circulatory support (MCS) has been rapid, and its use worldwide in patients with cardiogenic shock is increasingly widespread. However, current statistical data and clinical research..

Read More
thumbnail
0 comment

A Novel Approach to Measuring Physiologic Changes during Ambulation for a Patient with Post Infarct VSD Supported on Femoral IABP…

Abstract Post-infarct ventricular septal defect (PIVSD) is a rare, life-threatening complication following acute myocardial infarction (MI), associated with high overall mortality. Interventions include medical management, percutaneous closure, and/or surgical closure...

Read More
thumbnail
0 comment

Intraaortic Balloon Pump Counterpulsation, Part I: History, Technical Aspects, Physiologic Effects, Contraindications, Medical Applications/Outcomes

Abstract Intraaortic balloon pump counterpulsation is the most common form of mechanical circulatory support used in patients with myocardial ischemia and cardiogenic shock. The physiologic principles of counterpulsation include diastolic..

Read More
thumbnail
0 comment

Impact of prophylactic intra-aortic balloon pump on early outcomes in patients with severe left ventricular dysfunction undergoing elective coronary artery…

Abstract Objective Our aim was to analyse whether prophylactic preoperative intraaortic balloon pump (IABP) improves outcomes in hemodynamically stable patients with low  (LVEF ≤30%) undergoing elective  (CABG) using  (CPB). Secondary aim was to..

Read More
thumbnail
0 comment

Ambulation of Patients With In Situ Femoral Intraaortic Balloon Pump While Awaiting Heart Transplantation

Abstract With the implementation of the new allocation system in the United States on October 18, 2018, patients requiring temporary mechanical circulatory support (tMCS) have the highest priority, a shorter..

Read More
thumbnail
0 comment

Endothelial and Hemodynamic Function in a Large Animal Model in Relation to Different Extracorporeal Membrane Oxygenation Cannulation Strategies and Intra-Aortic…

Abstract Background: The use of simultaneous veno-arterial extracorporeal membrane oxygenation (ECMO) with or without an Intra-Aortic Balloon Pump (IABP) is a widely used tool for mechanical hemodynamic support. Endothelial function,..

Read More
thumbnail
0 comment

Effects of Intra-Aortic Balloon Pump delayed deflation timing on carotid blood flow and cardiac mechanics: An ultrasound and haemodynamic study

Abstract Intra-Aortic Balloon Pump (IABP) efficacy is critically affected by the inflation/deflation timing. Balloon deflation may cause a sucking effect, and a steal phenomenon on carotid flow. Delaying IABP deflation..

Read More
thumbnail
0 comment

Perfusionist removal of intra-aortic balloon pump catheters improves efficiency without an increase in complication rates

Abstract Introduction The intra-aortic balloon pump (IABP) is one of the most utilized cardiac assist devices. Patients receiving IABP therapy are typically managed in high acuity clinical care areas with..

Read More
thumbnail
0 comment

Ventricular Flow Dynamics with an Intra-Ventricular Balloon Pump: An In Vitro Analysis

Abstract Due to the high treatment costs associated with durable ventricular assist devices, an intra-ventricular balloon pump (IVBP) was developed to provide low-cost, short-term support for patients suffering from severe..

Read More
thumbnail
0 comment

Concomitant Intra-Aortic Balloon Pumping Significantly Reduces Left Ventricular Pressure during Central Veno-Arterial Extracorporeal Membrane Oxygenation—Results from a Large Animal Model

Abstract Introduction: Simultaneous ECMO and IABP therapy is frequently used. Haemodynamic changes responsible for the success of the concomitant mechanical circulatory support system approach are rarely investigated. In a large-animal..

Read More
thumbnail
0 comment

Concomitant ECMO And IABP Support in Postcardiotomy Cardiogenic Shock Patients

Abstract Objectives Simultaneous mechanical  (MCS) with intra-aortic balloon pump (IABP) to  (ECMO) is common in postcardiotomy  (PCS). This study aimed to analyse the effect of concomitant ECMO and IABP therapy on the short-term..

Read More
thumbnail
0 comment

Primary graft failure after cardiac transplantation: prevalence, prognosis and risk factors

Abstract Objectives: Primary graft failure (PGF) is a common and devastating complication, despite the advances in perioperative treatment. We aim to evaluate the prevalence of PGF and its impact on survival..

Read More
thumbnail
0 comment

Benefits of Intra-Aortic Balloon Pump Support in Patients with Postcardiotomy Shock Requiring Venoarterial Extracorporeal Membrane Oxygenation

Abstract Background: The benefit of the combined use of an intra-aortic balloon pump (IABP) and venoarterial extracorporeal membrane oxygenation (VA-ECMO) for postcardiotomy shock remains unclear. We aimed to analyse the potential..

Read More
thumbnail
0 comment

Clinical Outcomes and Cost Associated With an Intravascular Microaxial Left Ventricular Assist Device vs Intra-aortic Balloon Pump in Patients Presenting…

Abstract Importance  Intravascular microaxial left ventricular assist device (LVAD) compared with intra-aortic balloon pump (IABP) has been associated with increased risk of mortality and bleeding among patients with acute myocardial infarction..

Read More
thumbnail
0 comment

The Predictive Value of the 4Ts and HEP Score at Recommended Cutoffs in Patients With Mechanical Circulatory Support Devices

Abstract Objectives Despite the increasing utilization of mechanical circulatory support (MCS) devices, the 4Ts and heparin-induced thrombocytopenia (HIT) Expert Probability (HEP) scores have not been validated in patients with suspected..

Read More
thumbnail
0 comment

Intra-aortic Balloon Pump Use With Extra Corporeal Membrane Oxygenation—A Mock Circulation Loop Study

Abstract Venoarterial extracorporeal membrane oxygenation (ECMO) is used in cardiogenic shock refractory to inotropic support and intra-aortic balloon pump (IABP) support. Peripheral ECMO can lead to ventricular distention, and IABP..

Read More
thumbnail
0 comment

Erroneous Pressure Reading from an Unpowered Intra-aortic Balloon Pump: Case Report

Abstract Intra-aortic balloon pump (IABP) technology is an established treatment modality for patients with acute cardiac failure. Advances in IABP technology have simplified use and reliability such that electromechanical malfunctions..

Read More
thumbnail
0 comment

Postcardiotomy Venoarterial Extracorporeal Membrane Oxygenation With and Without Intra-Aortic Balloon Pump

Abstract Objectives To compare the outcomes of patients with postcardiotomy shock treated with venoarterial  (VA-ECMO) only compared with VA-ECMO and intra-aortic balloon pump (IABP). Design A retrospective multicenter registry study. Setting..

Read More
thumbnail
0 comment

Perioperative Spinal Cord Ischemia After Cardiac Surgery Not Involving the Aorta: A Review of the Literature

Abstract Spinal cord ischemia (SCI) associated with aortic surgery is well-described; however, SCI after cardiac surgery not involving the aorta is an unusual and underappreciated phenomenon. The authors reviewed the literature and found..

Read More
thumbnail
0 comment

Primary intra-aortic balloon support versus inotropes for decompensated heart failure and low output: a randomised trial

Abstract Aims: The haemodynamic effects of primary implantation of an intra-aortic balloon pump (IABP) versus inotropes in decompensated heart failure and low output (DHF-LO), but without an acute coronary syndrome, have..

Read More
thumbnail
0 comment

Concept and Design of a Novel Pulsatile Left Heart Assist Device—The PERKAT Left Ventricle System

Abstract Cardiogenic shock is associated with high mortality. Patients often require temporary mechanical circulatory support. We aimed to develop a percutaneously implantable, assist device that unloads the left ventricle (LV)..

Read More
thumbnail
0 comment

To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating…

Abstract ECMO is the most frequently used mechanical support for patients suffering from low cardiac output syndrome. Combining IABP with ECMO is believed to increase coronary artery blood flow, decrease..

Read More
thumbnail
0 comment

Veno-arterial extracorporeal membrane oxygenation with concomitant Impella versus concomitant intra-aortic-balloon-pump for cardiogenic shock

Abstract Introduction: The intra-aortic balloon pump (IABP) and Impella are left ventricular unloading devices with peripheral venoarterial extracorporeal membrane oxygenation (VA-ECMO) in place and later serve as bridging therapy when..

Read More
thumbnail
0 comment

Extracorporeal Membrane Oxygenation (ECMO) – Time is of the Essence!

Abstract Extra-corporeal membrane oxygenation (ECMO) is growing in adoption and popularity, as demonstrated by the international registry maintained by the Extracorporeal Life Support Organization (ELSO). While initially an adaptation of..

Read More
thumbnail
0 comment

Combined Use of Venoarterial Extracorporeal Membrane Oxygenation and Intra-Aortic Balloon Pump after Cardiac Arrest

Abstract Objectives We investigated whether intra-aortic balloon pump (IABP) combined with venoarterial extracorporeal membrane oxygenation (VA-ECMO) was associated with favourable neurological outcomes for patients after the return of spontaneous circulation..

Read More
thumbnail
0 comment

Antegrade IABPC insertion

Antegrade IABPC insertion and it's fixing for patient with aortoilliac occlusive disease.   [playlist ids="17155"] Dr.Sam Zeraatian Nejad Davani, CEO of rockingham medical research ADKWA center as well as Head..

Read More
thumbnail
0 comment

Intra-Aortic Balloon Pump Counterpulsation in the Post-Resuscitation Period is Associated with Improved Functional Outcomes in Patients Surviving an Out-of-Hospital Cardiac…

Abstract Background Despite advances in cardiopulmonary resuscitation, functional survival remains low after  (OOHCA).  (IABP) therapy has recently been shown to augment cerebral blood flow. Whether  therapy in the post-resuscitation period improves functional outcomes..

Read More
thumbnail
0 comment

Outcomes after intra-aortic balloon pump insertion in cardiac surgery patients

Abstract Objective: To assess whether preoperative versus intraoperative insertion of an intra-aortic balloon pump is associated with lower 30-day mortality or reduced length of hospital stay among patients who had..

Read More
thumbnail
0 comment

Intra‐aortic balloon pump counterpulsation (IABP) for myocardial infarction complicated by cardiogenic shock

Abstract Background Intra‐aortic balloon pump counterpulsation (IABP) is currently the most commonly used mechanical assist device for patients with cardiogenic shock due to acute myocardial infarction. Although there has been..

Read More