HAPTOGLOBIN DEPLETION DURING THE FIRST 7 DAYS OF VENO-VENOUS EXTRACORPOREAL MEMBRANE OXYGENATION THERAPY IS ASSOCIATED WITH INCREASED MORTALITY AND ADVERSE…

Abstract Background: Hemolysis is a frequent complication in patients with sepsis, ARDS, or extracorporeal membrane oxygenation (ECMO). Haptoglobin (Hp) can scavenge released cell-free hemoglobin (CFH). Hemolysis and low plasma concentrations of..

Read More
thumbnail
0 comment

Hemolysis Precedes Urine Color Change in Patients Undergoing Open-Heart Surgery on Cardiopulmonary Bypass

Abstract Purpose: Red-colored urine often occurs in patients in the perioperative period who undergo cardiac surgery using cardiopulmonary bypass (CPB). This urine color change has been utilized for approximating hemolysis..

Read More
thumbnail
0 comment

Multi-Method Investigation of Blood Damage Induced by Blood Pumps in Different Clinical Support Modes

Abstract To investigate the effects of blood pumps operated in different modes on nonphysiologic flow patterns, cell and protein function, and the risk of bleeding, thrombosis, and hemolysis, an extracorporeal..

Read More
thumbnail
0 comment

Hemolysis and cardiopulmonary bypass: meta-analysis and systematic review of contributing factors

Abstract Background The use of cardiopulmonary bypass (CPB) is almost inevitable in cardiac surgery. However, it can cause complications, including hemolysis. Until now, there have not been any standards for..

Read More
thumbnail
0 comment

Smaller Return Cannula in Venoarterial Extracorporeal Membrane Oxygenation Does Not Increase Hemolysis: A Single-Center, Cohort Study

Abstract The aim of this study was to explore the association between arterial return cannula diameter and hemolysis during peripheral VA ECMO. We identified 158 adult patients who received peripheral..

Read More
thumbnail
0 comment

Accelerated Hemocompatibility Testing of Rotary Blood Pumps

Abstract Ex vivo hemocompatibility testing is a vital element of preclinical assessment for blood-contacting medical devices. Current approaches are resource intensive; thus, we investigated the feasibility of accelerating hemocompatibility testing by standardizing..

Read More
thumbnail
0 comment

Effect of flow rate ratio and positioning on a lighthouse tip ECMO return cannula

Abstract Extracorporeal membrane oxygenation is a life-saving support therapy in the case of cardiopulmonary refractory failure. Its use is associated to complications due to the presence of artificial surfaces and..

Read More
thumbnail
0 comment

The Disconnect Between Extracorporeal Circulation and the Microcirculation: A Review

Abstract Extracorporeal circulation (ECC) procedures, such as cardiopulmonary bypass (CPB) and extracorporeal membrane oxygenation (ECMO), take over the function of one or more organs, providing clinicians time to treat underlying pathophysiological..

Read More
thumbnail
0 comment

Fatigue of red blood cells under periodic squeezes in ECMO

Abstract Hemolysis usually happens instantly when red blood cells (RBCs) rupture under a high shear stress. However, it is also found to happen gradually in the extracorporeal membrane oxygenation (ECMO)..

Read More
thumbnail
0 comment

Hemolysis in patients with Extracorporeal Membrane Oxygenation therapy for severe Acute Respiratory Distress Syndrome - a systematic review of the…

Abstract The Acute Respiratory Distress Syndrome (ARDS) is common in patients on the Intensive Care Unit and associated with significant mortality rates. In situations of severe respiratory insufficiency and failure..

Read More
thumbnail
0 comment

Hemolysis during Pediatric Extracorporeal Membrane Oxygenation: Associations with Circuitry, Complications, and Mortality

Abstract Objective: To describe factors associated with hemolysis during pediatric extracorporeal membrane oxygenation (ECMO), and the relationships between hemolysis, complications and mortality. Design: Secondary analysis of data collected prospectively by..

Read More
thumbnail
0 comment

Potential Factors for Poor Reproducibility of In Vitro Hemolysis Testing

Abstract In vitro testing of hemolysis is essential for the validation and development of ventricular assist devices. However, as many factors influence hemolysis, such tests’ inter- and intralaboratory reproducibility is poor...

Read More
thumbnail
0 comment

Association Between Hyperoxemia and Increased Cell-Free Plasma Hemoglobin During Cardiopulmonary Bypass in Infants and Children

Abstract OBJECTIVES:  To determine potential risk factors for severe hemolysis during pediatric cardiopulmonary bypass and examine whether supraphysiologic levels of oxygen and cardiopulmonary bypass duration are associated with hemolysis. DESIGN: ..

Read More
thumbnail
0 comment

A retrospective analysis of the hemolysis occurrence during extracorporeal membrane oxygenation in a single center

Abstract Introduction Extracorporeal membrane oxygenation (ECMO)–associated hemolysis still represents a serious complication. The present study aimed to investigate those predictive factors, such as flow rates, the use of anticoagulants, and..

Read More
thumbnail
0 comment

Surgically Implanted Impella Device for Patients on Impella CP Support Experiencing Refractory Hemolysis

Abstract The Impella CP (Abiomed Inc., Danvers, MA) is widely used in cardiac catheterization laboratories for patients presenting with cardiogenic shock, but it is also known to cause significant hemolysis. The risk..

Read More
thumbnail
0 comment

The Disconnect Between Extracorporeal Circulation and the Microcirculation

Abstract Extracorporeal circulation (ECC) procedures, such as cardiopulmonary bypass (CPB) and extracorporeal membrane oxygenation (ECMO), take over the function of one or more organs, providing clinicians time to treat underlying..

Read More
thumbnail
0 comment

Automated and cost-efficient early detection of hemolysis in patients with extracorporeal life support: Use of the hemolysis-index of routine clinical…

Abstract Purpose Patients with  (ECLS) are at risk for hemolysis-related complications. Therefore, monitoring of free hemoglobin (fHb) levels is indicated. Conventional methods for fHb are laborious and not always available. Here..

Read More
thumbnail
0 comment

Magnetic levitation pump versus constrained vortex pump: a pilot study on the hemolysis effect during minimal invasive extracorporeal circulation

Abstract Background Elevated plasma free hemoglobin is associated with multi-organ injury. In this context, minimally invasive extracorporeal technologies represent a way to reduce this complication following cardiac surgery. Methods We..

Read More
thumbnail
0 comment

Flow characteristics and hemolytic performance of the new Breethe centrifugal blood pump in comparison with the CentriMag and Rotaflow pumps

Abstract Blood pumps have been increasingly used in mechanically assisted circulation for ventricular assistance and extracorporeal membrane oxygenation support or during cardiopulmonary bypass for cardiac surgery. However, there have always..

Read More
thumbnail
0 comment

The Optimal Cell Salvage Settings to Maximize Hematocrit and Minimize Potassium Using the Cobe BRAT2 Autologous Blood Recovery Unit

Abstract Objective The objective was to determine the optimal cell saver device settings (infusion rate and wash rate) at which hematocrit is preserved and potassium and lactate are removed from..

Read More
thumbnail
0 comment

Perioperative Serum Free Hemoglobin and Haptoglobin Levels in Valvular and Aortic Surgery With Cardiopulmonary Bypass: Their Associations With Postoperative Kidney…

Abstract Highlights • Hemolysis due to CPB leads to an increase of serum free Hemoglobin(fHb) level. • Increase of serum fHb level had an independent association with postoperative AKI. •..

Read More
thumbnail
0 comment

Carboxyhemoglobin Elevation, a Marker for Hemolysis, Is Common in Veno-venous Extracorporeal Membrane Oxygenation

Abstract Giani et al. found low levels of carboxyhemoglobin (COHb) in a cohort of patients supported on veno-venous extracorporeal membrane oxygenation (VV ECMO) at their center. It is noteworthy that even on..

Read More
thumbnail
0 comment

Hemodilution Increases the Susceptibility of Red Blood Cells to Mechanical Shear Stress During In Vitro Hemolysis Testing

Abstract The American Society for Testing and Materials (ASTM) F1841 standard for the assessment of hemolysis in blood pumps recommends using phosphate-buffered saline (PBS) for hemodilution to standardize hematocrit (HCT)...

Read More
thumbnail
0 comment

Dynamics of Blood Flows in Aortic Stenosis: Mild, Moderate, and Severe

Abstract Supraphysiologic high shear stresses created in calcific aortic stenosis (AS) are known to cause hemostatic abnormalities, however, the relationship between the complex blood flows over the severity of AS..

Read More
thumbnail
0 comment

Performance characteristics of the new Eurosets magnetically suspended centrifugal pump

Abstract Objective: The aim was to evaluate the performance of a newly developed magnetically suspended centrifugal pump head intended for use as a ventricular assistance device with a newly developed..

Read More
thumbnail
0 comment

Platelet, Red Cell, and Endothelial Activation and Injury During Extracorporeal Membrane Oxygenation

Abstract Extracorporeal membrane oxygenation (ECMO) can be lifesaving but suffers from high rates of bleeding and repeated transfusions. Current monitoring of blood cell damage during ECMO is limited to platelet..

Read More
thumbnail
0 comment

Unexplained hemolysis in patients undergoing ECMO: beware of hypertriglyceridemia

Abstract Hemolysis is a common complication of extracorporeal membrane oxygenation (ECMO) support and is associated with increased mortality. Frequent monitoring of markers of hemolysis is performed at ECMO centers. We..

Read More
thumbnail
0 comment

Hemolytic characteristics of three suctioning systems for use with a newly developed cardiopulmonary bypass system

Abstract Introduction: We have been developing a closed-circuit cardiopulmonary bypass (CPB) system (“Dihead CPB”) for application during coronary artery bypass grafting (CABG) and valve surgery. To strive for minimal hemolysis..

Read More
thumbnail
0 comment

Hemolytic characteristics of three suctioning systems for use with a newly developed cardiopulmonary bypass system

Abstract Introduction: We have been developing a closed-circuit cardiopulmonary bypass (CPB) system (“Dihead CPB”) for application during coronary artery bypass grafting (CABG) and valve surgery. To strive for minimal hemolysis..

Read More
thumbnail
0 comment

Hemolytic characteristics of three suctioning systems for use with a newly developed cardiopulmonary bypass system

Abstract Introduction: We have been developing a closed-circuit cardiopulmonary bypass (CPB) system (“Dihead CPB”) for application during coronary artery bypass grafting (CABG) and valve surgery. To strive for minimal hemolysis..

Read More