Abstract In magnetically levitated rotodynamic blood pumps (RPBs), the impeller position depends on a balance of electromagnetic and fluid dynamic forces. The aim of this study was to describe the..
Read MoreAbstract A 70-year-old patient with idiopathic dilated cardiomyopathy underwent implantation of a HeartMate III left ventricular assist device (LVAD) at INTERMACS IV. Postoperatively, right ventricular (RV) failure was managed with..
Read MoreAbstract Terminal heart failure presents challenges, requiring cardiac transplantation, or mechanical circulatory support. Limited donor organ availability has made mechanical support crucial. Advances in centrifugal-flow systems, compared to axial-flow, have..
Read MoreAbstract We describe a 15 year old patient with failing second-stage single-ventricle palliation and left pulmonary artery thrombosis successfully supported with HeartMate 3 ventricular assist device and a Fontan completion..
Read MoreAbstract Heart failure with preserved ejection fraction (HFpEF) constitutes approximately 50% of heart failure (HF) cases, and encompasses different phenotypes. Among these, most patients with HFpEF exhibit structural heart changes,..
Read MoreAbstract Objectives Right ventricular failure following implantation of a durable left ventricular assist device (LVAD) is a major driver of mortality. Reported survival following biventricular (BiVAD) or total artificial heart..
Read MoreAbstract Background The efficacy of extracorporeal membrane oxygenation (ECMO) as a bridge to left ventricular assist device (LVAD) remains unclear, and recipients of the more contemporary HeartMate 3 (HM3) LVAD..
Read MoreAbstract Purpose The HeartMate 3 (HM3) left ventricular assist device (LVAD) has demonstrated excellent clinical outcomes; however, pump speed optimization is challenging with the available HM3 monitoring. Therefore, this study..
Read MoreAbstract Background The removal of the HeartWare ventricular assist device (HVAD) due to pump malfunctions and inferior outcomes compared to HeartMate 3 (HM3) in adults has created a care gap..
Read MoreAbstract Background Clinical trials inform on average efficacy, but individualized risk assessments for outcome prediction are important in guiding treatment implementation. Objectives The authors developed and validated a patient-specific risk..
Read MoreAbstract The implantation of the left ventricular assist device Abbott HeartMate 3TM is being increasingly performed for management of end-stage heart failure. LVAD implantation might be associated with early or..
Read MoreAbstract The need for biventricular support poses significant challenges for patients who require a mechanical bridge to transplantation. Recent improvements in ventricular assist device (VAD) technology has made possible the..
Read More