Zuhause

thumbnail
0 Kommentar

Observational study of thrombosis and bleeding in COVID-19 VV ECMO patients

Abstract Introduction: COVID-19 has been associated with increased risk of thrombosis, heparin resistance and coagulopathy in critically ill patients admitted to intensive care. We report the incidence of thrombotic and..

Weiterlesen
thumbnail
0 Kommentar

Hypofibrinogenemia can be estimated by the predictive formula in aortic surgery

Abstract Objective Aortic surgery often causes massive bleeding due to hypofibrinogenemia. Predicting hypofibrinogenemia is useful for developing a hemostasis strategy, including preparing for blood transfusion. We made a formula for..

Weiterlesen
thumbnail
0 Kommentar

Correlating Oxygen Delivery on Cardiopulmonary Bypass with Society of Thoracic Surgeons Outcomes Following Cardiac Surgery

Abstract Background The relationship between low oxygen delivery (DO2) on cardiopulmonary bypass and morbidity and mortality following cardiac surgery remains unexamined. Methods We reviewed patients undergoing Society of Thoracic Surgeons..

Weiterlesen
thumbnail
0 Kommentar

Mitral valve surgery: current status and future prospects of the minimally invasive approach

Abstract Introduction. During the past five years the approach to procedural planning, operative techniques and perfusion strategies for minimally invasive mitral valve surgery (MIMVS) has evolved. With the goal to..

Weiterlesen
thumbnail
0 Kommentar

Xtra: The extraordinarily innovative, intuitive and powerful ATS system

Many health care providers and hospitals are now developing a Blood Management Strategy, a multidisciplinary approach to optimize the use of blood products, aiming to reduce the need for homologous..

Weiterlesen
thumbnail
0 Kommentar

S5: The world-leading perfusion system

The console housing accommodates the entire electronics of the E/P pack including the central power supply and the uninterruptible emergency power supply. The four castors of the console can be..

Weiterlesen
thumbnail
0 Kommentar

Connect, get connected to optimal data management practices

The Connect workflow system minimizes transcription errors, bias and all the drawbacks associated with manual operations. Connect allows trending and electronic transfer of data from LivaNova disposables. [pdf-embedder url="https://perfusfind.com/wp-content/uploads/2021/02/Catalogo-CONNECT-Palex_compressed.pdf" title="Catálogo..

Weiterlesen
thumbnail
0 Kommentar

Bi-Flow Arterial Cannula: Bidirectional perfusion in one unique cannula

The innovative, patented and award-winning design of the Bi-Flow cannula incorporates a unique shoulder and downstream perfusion channel. These features make Bi-Flow the only cannula able to provide continuous, reliable..

Weiterlesen
thumbnail
0 Kommentar

Hemoadsorption to treat severe iatrogenic intoxication to Patent Blue: A Case Report

This case reports on a 27-year-old woman (body weight 45 kgs), who was admitted to the Emergency Department of a peripheral hospital in Brussels due to intoxication of unknown origin...

Weiterlesen
thumbnail
0 Kommentar

Organ donation after controlled cardiocirculatory death: confidence by clarity

Abstract Even if an impressive number of 6.337 organs from 1837 donors were transplanted in the Eurotransplant region in 2020 (a reduction of 667 donors compared to 2019), at the..

Weiterlesen
thumbnail
0 Kommentar

ELSA, Extracorporeal Life Support Assurance

With Recirculation Percentage, Oxygenator Clot Detection, and Delivered Pump Flow Verification. With an injection of a small volume of saline, the ELSA Monitor measures oxygenator blood volume to identify early..

Weiterlesen
thumbnail
0 Kommentar

FLOW XL, medidor de flujo

TRANSONIC presenta FlowXL, su nuevo sistema multidisciplinar de medición de flujo basado en el gold estándar TTFM, que permite obtener las medidas más precisas. [pdf-embedder url="https://perfusfind.com/wp-content/uploads/2021/02/FlowXL-Configurations-Brochure-4-hojas_compressed.pdf" title="FlowXL Configurations Brochure (4..

Weiterlesen
thumbnail
0 Kommentar

Mechanisms of oxidative stress and myocardial protection during open-heart surgery

Abstract We investigated MBL2 and MASP2 genotypes, serum MBL (mannose-binding lectin) levels and activities of its complexes with associated serine Cold heart protection via cardioplegia administration, limits the amount of oxygen demand. Systemic normothermia..

Weiterlesen
thumbnail
0 Kommentar

The effect of obesity on acute kidney injury after cardiac surgery

Abstract Objective Postoperative  is a frequent and serious consequence of cardiac surgery. We undertook to investigate the association of obesity and the risk of acute kidney injury development after cardiac surgery...

Weiterlesen
thumbnail
0 Kommentar

Cytoreduction and hyperthermic intraperitoneal chemotherapy: The learning curve reassessed

Abstract Background  and  (CRS-HIPEC) is now the preferred treatment of many peritoneal surface malignancies. In this retrospective study we aimed to analyze how several performance indicators changed during the first 100..

Weiterlesen
thumbnail
0 Kommentar

Inotropes

Abstract  are a heterogenous group of drugs that modify calcium handling and alter the force of . , and their synthetic analogues, increase  by activating cyclic adenosine monophosphate (cAMP) or  (IP3).  block , which in turn..

Weiterlesen
thumbnail
0 Kommentar

Mannose-binding lectin (MBL) insufficiency protects against the development of systemic inflammatory response after pediatric cardiac surgery

Abstract We investigated MBL2 and MASP2 genotypes, serum MBL (mannose-binding lectin) levels and activities of its complexes with associated serine proteases (MASP-1, MASP -2), in relation to complications following cardiac surgery in 195 children...

Weiterlesen
thumbnail
0 Kommentar

Vasopressinase Activity: A Potential Early Biomarker for Detecting Cardiopulmonary Bypass-Associated Acute Kidney Injury?

Abstract Background Acute kidney injury (AKI) is a common and serious complication of surgeries that include cardiopulmonary bypass (CPB). Currently, increases in serum creatinine levels are used to diagnose AKI,..

Weiterlesen
thumbnail
0 Kommentar

Principles of cardiac anaesthesia

Abstract Cardiac surgical outcomes in the UK have consistently improved despite increasing procedure complexity and ‘sicker’ patients. Numerous anaesthetic techniques are employed with no definitive evidence clearly demonstrating superiority of..

Weiterlesen
thumbnail
0 Kommentar

Migrated Avalon Veno‐Venous Extracorporeal Membrane Oxygenation Cannula: How to Adjust Without Interruption of Flow

Abstract The Avalon dual lumen cannula is presently the cannula of choice for veno‐venous extracorporeal membrane oxygenation (VV‐ECMO) via right internal jugular cannulation. This cannula establishes VV‐ECMO with a single..

Weiterlesen
thumbnail
0 Kommentar

Intraoperative Magnesium Administration Does Not Reduce Postoperative Atrial Fibrillation After Cardiac Surgery

Abstract BACKGROUND:  Hypomagnesemia has been associated with an increased risk of postoperative atrial fibrillation (POAF). Although previous studies have suggested a beneficial effect of magnesium (Mg) therapy, almost all of..

Weiterlesen
thumbnail
0 Kommentar

Noninvasive strategies in COVID-19: epistemology, randomised trials, guidelines, physiology

Abstract COVID-19 is producing seismic changes in society at large and the action of doctors is receiving greater attention from the public than ever in our lifetime. The medical care..

Weiterlesen
thumbnail
0 Kommentar

Hospital Clínico Universitario de Valencia

Centro de referencia en monitorización avanzada en perfusión. Sistema CONNECT perfusclin@gmail.com

Weiterlesen
thumbnail
0 Kommentar

Performer HT, innovación, eficiencia y seguridad dentro del quirófano.

Las prestaciones del sistema Performer han permitido el desarrollo del sistema innovador Performer HT, el nuevo equipo de Rand, diseñado para Perfusión Hipertérmica Intraperitoneal/Intrapleural (HIPEC/HITHOC) y Perfusión de Miembros (ILP)..

Weiterlesen
thumbnail
0 Kommentar

Performer HT

Un diseño innovador con altas prestaciones en el control especifico y la monitorización de la hipertermia, máxima simplificación del manejo intraoperatorio y un alto nivel de seguridad son las principales..

Weiterlesen
thumbnail
0 Kommentar

Perfusión hipertérmica en la práctica clínica

La carcinomatosis peritoneal está causada por la difusión trancoelemica de células cancerígenas que tienen su origen, o bien en tumores primarios peritoneales, o en tumores de órganos y vísceras contenidos..

Weiterlesen
thumbnail
0 Kommentar

HANG & GO, kit Performer HT

El Kit de un solo uso Hang & Go para perfusión hipertérmica intraperitoneal/intrapleural está disponible en 2 versiones. El Kit incluye todo el material necesario para realizar un tratamiento.  ..

Weiterlesen
thumbnail
0 Kommentar

Vídeos quirúrgicos Performer HT

Accede a los vídeos quirúrgicos Performer HT, de RanD

Weiterlesen
thumbnail
0 Kommentar

Publicaciones Performer HT

Accede a la publicaciones Performer HT, de RanD

Weiterlesen
thumbnail
0 Kommentar

Altered kinetics of circulating progenitor cells in cardiopulmonary bypass (CPB) associated vasoplegic patients: A pilot study

Abstract Vasoplegia observed post cardiopulmonary bypass (CPB) is associated with substantial morbidity, multiple organ failure and mortality. Circulating counts of hematopoietic stem cells (HSCs) and endothelial progenitor cells (EPC) are..

Weiterlesen