Abstract
The present study compared the clinical outcome between endo-aortic balloon occlusion (EABO) and transthoracic clamping (TTC) in patients undergoing minimally invasive mitral valve surgery (MIMVS).
All patients from the Mini-Mitral International Registry undergoing MIMVS were primarily considered for study inclusion. One-to-one nearest neighbour propensity score matching considering clinically relevant baseline covariates. The matched cohort was investigated regarding the clinical outcome between EABO and TTC according to the end-point definitions of the Mitral Valve Academic Research Consortium.
From 2015 to 2021, a total of 6884 patients were primarily included in the study. Propensity score matching resulted in a population of 733 matched pairs. Patients treated with EABO showed significantly lower rates of conversion to sternotomy (13 [1.8%] vs 34 [4. 6%]; P = .001), longer cardiopulmonary bypass time (124 min [105-147] vs 120 min [90-148]; P = .001), and a longer intubation time (11.8 h [7.9-22.2] vs 10.8 h [6.4-20.0]; P < .001). No statistically significant differences were observed regarding postoperative mortality, stroke, bleeding requiring revision, vascular complications, intensive care unit stay, or hospital length of stay.
In patients undergoing MIMVS, EABO and TTC are excellent options for aortic clamping. EABO showed benefits over TTC with lower rates of conversion to full sternotomy.